Question No : 1


A customer has filled out the Installation Workbook. The management IP information netmask is specified as “255.255.255.223” and the gateway is specified as “10.24.18.1”.
What corrective action should be taken to reconcile the IP configuration?

정답:
Explanation:
The provided netmask "255.255.255.223" is invalid. Changing it to the standard subnet mask "255.255.255.0" aligns correctly with the gateway "10.24.18.1" for proper network configuration.

Question No : 2


The customer has completed the installation document and has stated that the proxy server address is “10.24.18.120”.
What additional information is required?

정답:
Explanation:
To properly configure the proxy server, both the protocol prefix (e.g., http:// or https://) and the port number are required along with the IP address.

Question No : 3


A customer would like to reduce SafeMode settings for retention and eradication with their current policy.
How is authorization obtained to make the requested changes?

정답:
Explanation:
Reducing SafeMode retention and eradication settings requires approval from two designated SafeMode approvers via Pure1’s step-up authentication to ensure secure and authorized policy changes.

Question No : 4


Before proceeding with a controller upgrade, phonehome logs must be sent.
What command will verify that the logs have been sent?

정답:
Explanation:
The command purearray phonehome --status provides the current status of Phonehome log transmissions, confirming whether logs have been successfully sent before an upgrade.

Question No : 5


Which Purity command can be used to validate I/O is balanced across initiators?

정답:
Explanation:
The purehost iobalance --check command validates whether I/O is balanced evenly across initiators, helping ensure optimal performance and distribution.

Question No : 6


What slot does a PCIe SAS card need to be installed in a FlashArray//XR2/3?

정답:
Explanation:
In FlashArray//XR2 and //XR3 models, the PCIe slot 2 is designated for the installation of a 4-port SAS card. This configuration is essential for connecting to SAS expansion shelves, ensuring proper data path redundancy and performance.

Question No : 7


What is the minimum AC voltage required to operate a FlashArray//X20R4 array?

정답:
Explanation:
The FlashArray//X20R4 requires a minimum AC input voltage of 180V to operate. This ensures stable power delivery for the array's components.

Question No : 8


After an Implementation Engineer installs a new FlashArray and runs health checks, they see that Phonehome and Remote Assist are NOT working correctly.
Which outbound port needs to be open for all management ports (physical and virtual)?

정답:
Explanation:
Port 443 (HTTPS) must be open on all management ports to enable secure outbound connections for Phonehome and Remote Assist functionality.

Question No : 9


A customer would like to consolidate their SAS shelves and wants to evacuate multiple shelves in parallel.
What is a prerequisite for this procedure?

정답:
Explanation:
To evacuate multiple shelves in parallel safely during consolidation, the array’s usage must be sufficiently low (under 60%) to ensure enough free capacity for data movement.

Question No : 10


If drives need to be relocated within an array for an XFORM upgrade, when should this be completed?

정답:
Explanation:
Drive relocation should be performed only after the XFORM upgrade completes to avoid disrupting the upgrade process and ensure data integrity.

Question No : 11


A client needs to upgrade Purity on their FlashArray, but is unable to wait for an available upgrade date from support.
What action should the customer take?

정답:
Explanation:
Customers can independently upgrade Purity using the Self-Service upgrade portal on Pure1 Manage, enabling them to proceed without waiting for support scheduling.

Question No : 12


Which command should an Implementation Engineer use to allow Support access to an array?

정답:
Explanation:
The purearray remoteassist --connect command explicitly enables Support to establish a remote connection to the array for troubleshooting or assistance.

Question No : 13


After running puredb run giveback --safe command once CT0 has been upgraded, how long should the Implementation Engineer wait before continuing with the controller upgrade?

정답:
Explanation:
Waiting 10 minutes after running puredb run giveback --safe ensures the system completes safe resource rebalancing and stabilizes before proceeding with the next controller upgrade step.

Question No : 14


For FlashArray//XL, which 2 PCIe slots should be used for DFS connectivity?

정답:
Explanation:
On FlashArray//XL, PCIe slots 0 and 6 are designated for DirectFlash Shelf (DFS) connectivity to optimize data throughput and redundancy.

Question No : 15


The Customer’s Implementation Workbook specifies that the SMTP reply is “outlook.microsoft.com:587”.
What correction should be made for array initialization to be successful?

정답:
Explanation:
For SMTP settings during array initialization, the host should be specified without the port number; including “:587” can cause connection issues and prevent successful initialization.