Exin Certified Data Centre Professional 온라인 연습
최종 업데이트 시간: 2025년08월19일
당신은 온라인 연습 문제를 통해 EXIN Exin-CDCP 시험지식에 대해 자신이 어떻게 알고 있는지 파악한 후 시험 참가 신청 여부를 결정할 수 있다.
시험을 100% 합격하고 시험 준비 시간을 35% 절약하기를 바라며 Exin-CDCP 덤프 (최신 실제 시험 문제)를 사용 선택하여 현재 최신 40개의 시험 문제와 답을 포함하십시오.
정답:
Explanation:
According to the EPI Data Centre Professional (CDCP®) Reference Materials, the recommended number of monitoring points for temperature measurement in a data centre is 3 per rack: one at the top, one at the middle, and one at the bottom1. This is to ensure that the temperature distribution within the rack is uniform and within the acceptable range for the equipment. The temperature sensors should be placed at the front of the rack, where the air enters the equipment, and not at the back, where the hot air exits1.
Reference: 1: EPI Data Centre Professional (CDCP®) Reference Materials, page 23.
정답:
Explanation:
MTBF stands for Mean Time Between Failures, and it is the arithmetic mean of time between the failing and the subsequent running of the system in a particular time period. MTBF is a measure of reliability that indicates how often a system or component fails during its operation. MTBF can be calculated by dividing the total operating time by the number of failures over a given period.
For example, if a system operates for 1000 hours and experiences 5 failures, the MTBF is 1000/5 = 200 hours.
Reference: EPI Data Centre Training Framework, CDCP Preparation Guide, MTBF, MTTR, MTTF, MTTA:
Understanding incident metrics - Atlassian
정답:
Explanation:
An ultrasonic humidifier is a type of cool mist humidifier that uses a metallic diaphragm that vibrates at high frequencies to create water droplets that are added to the air. A fan projects these droplets into the air as mist, which then evaporates and humidifies the room. This type of humidifier rapidly vibrates the water to create a fog or mist.
Reference: EPI Data Centre Training Framework, How Humidifiers Can Help Allergies, Humidifier Buying Guide: Pros and Cons of Different Types.
정답:
Explanation:
According to the IEEE definition, reliability is the ability of a system or component to perform its required functions under stated conditions for a specified period of time. Reliability is a measure of how often a system or component fails, and how long it takes to recover from a failure. Reliability is closely related to availability, which is the degree to which a system or component is operational and accessible when required for use. Reliability and availability are both affected by factors such as design, maintenance, testing, and environmental conditions.
Reference: EPI Data Centre Training Framework, CDCP Preparation Guide, Reliability engineering - Wikipedia
정답:
Explanation:
A computer room air handling unit (CRAH) is a device that uses circulating chilled water to remove heat from the data center environment. A CRAH consists of a fan, a coil, and a filter. The fan draws the warm air from the data center and passes it through the coil, where the heat is transferred to the chilled water. The chilled water is supplied by a chiller or a cooling tower, and the cooled air is returned to the data center. A CRAH is different from a computer room air conditioning unit (CRAC), which uses a refrigerant instead of chilled water to cool the air.
Reference:
• EPI Data Centre Professional (CDCP®) Preparation Guide, page 36
• Chilled Water Systems: Applications and Common Uses
• The Principles of Basic Refrigeration: What is a chiller?
정답:
Explanation:
Availability is the degree to which a system, product or component is operational and accessible when required for use. It is one of the attributes of reliability, which is the ability of a system or component to perform its required functions under stated conditions for a specified period of time. Availability can be calculated as the ratio of the expected value of the uptime (the time when the system is functional) to the total time (uptime plus downtime) of a system or component. Availability can also be influenced by factors such as maintainability, fault tolerance, redundancy, diagnostics, and logistics.
Reference: EPI Data Centre Professional (CDCP®) Preparation Guide, page 8; Availability - Wikipedia; Reliability - ISO 25000.
정답:
Explanation:
The fire triangle is a simple model that illustrates the three elements that a fire needs to ignite and sustain: oxygen, heat, and fuel. Oxygen is the oxidizing agent that enables the combustion reaction, heat is the energy source that raises the temperature of the fuel to its ignition point, and fuel is the material that reacts with oxygen and releases heat and light. Removing any one of these elements can extinguish a fire. For example, water can reduce the heat and the oxygen, sand or soil can smother the fuel and the oxygen, and fire extinguishers can displace the oxygen or lower the temperature.
Reference: EPI Data Centre Professional (CDCP®) Reference Materials, page 66. EPI Data Centre
Framework, Module 4: Fire Protection, page 4. 1, 2, 3.
정답:
Explanation:
Measuring “Business Values” begins first with budgeting and identifying the costs associated with the project. This includes understanding the economic impact of the project, such as the cost of labor, materials, and other resources. It is also important to evaluate the return on investment (ROI) of the project, which will help to determine its overall value. Additionally, it is important to consider the long-term impact of the project and its potential to add value to the business in the future.
정답:
Explanation:
According to the CDCP® Preparation Guide, an audible signaling and notification device is a device that produces a sound to alert or notify the occupants of a data center of an event or condition. Sirens are examples of such devices, as they can emit loud and distinctive tones to warn of fire, emergency, or security incidents. Strobes, on the other hand, are visual signaling and notification devices that produce flashes of light to attract attention or convey information. Alarms and clocks are not specific types of devices, but rather general terms that can refer to various audible or visual devices.
Reference: CDCP® Preparation Guide, page 30. Audible Visual Notification | System Sensor | Honeywell. Audible-Visual Signaling Devices - Automation Direct.
정답:
Explanation:
Measuring business value is the process of assessing the benefits and costs of IT investments and initiatives in relation to the strategic objectives and priorities of the organization. One of the factors that can be used to measure business value is scalability, which is the ability of a system or component to handle increasing workloads or demands without compromising performance, quality, or functionality. Scalability is important for business value because it enables the organization to adapt to changing market conditions, customer expectations, and growth opportunities. Scalability can also reduce operational costs, increase efficiency, and improve customer satisfaction. Therefore, scalability is one of the factors that can be used in measuring business value.
Reference:
• EPI Data Centre Training Framework1
• EPI Data Centre Competence Framework2
• Measuring the Business Value of IT3
• How to Measure the Business Value with Effective Data Quality Governance
• 7 Rules for Demonstrating the Business Value of IT
정답:
Explanation:
According to the EPI Data Centre Professional (CDCP®) Preparation Guide, failure is defined as “the termination of the ability of a product to perform its required function” (page 9). Failure can occur due to various reasons, such as wear and tear, design flaws, human errors, environmental factors, or external events. Failure can affect the availability, reliability, and performance of a product, system, or service.
Reference:
• EPI Data Centre Professional (CDCP®) Preparation Guide, page 9
• What is Failure? | Definition from WhatIs.com
정답:
Explanation:
A steam canister humidifier is a type of humidifier that uses electricity to heat water in a canister containing electrodes. The water conductivity and the water level determine the amount of current and steam production. The steam canister humidifier is also known as an electrode boiler humidifier or an electrode steam humidifier123.
Reference: 1: EPI Data Centre Professional (CDCP®) Reference Materials, page 192: Electrode and resistive type humidifiers compared | steamovap technologies inc3: Know-How | Electrode Steam Humidifier - Condair Group.
정답:
Explanation:
Legal fees are an example of direct cost because they can be directly attributed to a specific project, product, or service. Legal fees are incurred for the purpose of obtaining legal advice, drafting contracts, resolving disputes, or complying with regulations related to the core business activity. Legal fees are not general overhead expenses that are shared by multiple cost objects.
Reference: EPI Data Centre Training Framework, CDCP Preparation Guide, Direct Cost - Overview, Examples, Tax Implications
정답:
Explanation:
Damaged brand perception is an example of an indirect cost because it is not directly related to a specific product or service, but rather to the overall reputation and image of the company. Damaged brand perception can result from various factors, such as poor quality, customer dissatisfaction, security breaches, or negative publicity. Damaged brand perception can affect the company’s ability to attract and retain customers, partners, and investors, and thus reduce its profitability and competitiveness.
Reference: EPI Data Centre Training Framework, Indirect Cost: Definition and Example, What Is Indirect Cost? Definition, Types and Examples.
Learn more
1 indeed.com2 o
정답:
Explanation:
Mean time between failures (MTBF) is a measure of the reliability of a system or component. It represents the average time that a system or component will operate before it fails. The higher the MTBF, the more reliable the system or component is. MTBF is calculated by dividing the total time of operation by the number of failures that occur during that time. MTBF is used to compare the reliability of similar systems or components, and to help with maintenance planning, inventory management, and system design.
Reference: EPI Data Centre Training Framework, CDCP Preparation Guide, Reliability Metrics 101:
Mean Time Between Failure (MTBF)